Atomic Absorption Spectrophotometer FM-AAS-A200 is an air-acetylene flame-only system with a true double-beam design for fast start-up and exceptional long-term stability. Features cutting-edge fiber optics to maximize light throughput for improved detection limits, as well as two-lamp mount, and automated flame and burner assembly optimization for enhanced productivity. Fitted out with single beam, Czerny-Turner design grating monochromator 1800 lines/mm, D2 lamp background correction capability and Cu, Mn, Hg hollow cathode lamps for elemental analysis.
$16,550.00
| Wavelength Range | 190 to 900 nm |
| Wavelength Accuracy | ±0.5 nm |
| Resolution | Two spectral lines of Mn at 279.5 nm and 279.8 nm, separable with spectral bandwidth of 0.2 nm and valley-peak energy ratio < 30% |
| Baseline Stability | 0.005 A/30 min |
| Background Correction | D₂ lamp background correction, capability at 1A is better than 30 times |
| Lamp Turret | 2 lamps powered simultaneously (one preheated) |
| Lamp Current Adjustment | 0 to 20 mA |
| Lamp Power Supply Mode | 400 Hz square wave pulse |
| Monochromator | Single beam, Czerny-Turner design grating monochromator |
| Grating | 1800 lines/mm |
| Focal Length | 277 mm |
| Blazed Wavelength | 250 nm |
| Spectral Bandwidth | 0.1 nm, 0.2 nm, 0.4 nm, 1.2 nm (automatic change) |
| Spectral Adjustment | Manual adjustment for wavelength and slit |
| Burner | 10 cm single-slot all-titanium burner |
| Spray Chamber | Corrosion-resistant all-plastic spray chamber |
| Nebulizer | High-efficiency glass nebulizer with metal sleeve, sucking up rate: 6-7 ml/min |
| Position Adjustment | Manual adjustment for vertical, horizontal positions, and burner rotation angle |
| Gas Line Protection | Fuel gas leakage alarm |
| Detector | R928 Photomultiplier with high sensitivity and wide spectral range |
| Electronic & Micro-computer System | Automatic adjustment of light source power, light energy, and negative high-voltage auto-balance |
| Display Mode | LED display of energy, measurement values, and direct concentration reading |
| Read Mode | Transient, time average, peak height, peak area, integral time selectable (0.1 to 19.9 s) |
| Scale Expansion | 0.1 to 99 |
| Data Processing Mode | Automatic calculation of mean, standard deviation, and relative standard deviation (Reporting range: 1 to 99) |
| Measurement Mode | Automatic curve fitting with 3 to 7 standards, sensitivity auto-correction |
| Result Printing | Measurement data, working curve, signal profile, and analytical conditions |
| Instrument Self-check | Checks current status of each function key |
| Characteristic Concentration of Cu | ≤0.025 mg/L |
| Detection Limit of Cu | ≤0.006 mg/L |
| Power Supply | AC 220 V, 50 Hz |
| Dimension | 1020 × 490 × 540 mm |
| Net weight | 80 kg |
| Gross weight | 95 kg |
1. Air Compressor
2. Hydride Vapor Generator
3. Hydride Vapor Generator (Peristaltic Pump Type)
4. High-Efficiency Glass Nebulizer
5. Water Chiller
Fison Atomic Absorption Spectrophotometers offer high precision and sensitivity for detecting metal concentrations in various samples. They feature an advanced optical system with a high-resolution monochromator for enhanced spectral accuracy. These units provide automated sample handling, reducing manual intervention. They include a user-friendly interface and digital controls for easy operation. Our spectrophotometers deliver multiple calibration modes, allowing single and multi-element analysis to ensure versatility.